Description
High-quality autoclaves
Lafomed - an autoclave brand recognised in more than 50 countries worldwide. The devices comply with medical standards and directives, have a low failure rate and feature latest-generation electronic modules in their microprocessors. Lafomed autoclaves suit salons that work intensively and cannot afford technical failures during the working day - reliability and simple operation let you focus on clients rather than on equipment maintenance.
Intended use
The LFSS12AA LCD model is designed to sterilise invasive medical devices and prevent cross-contamination - critically important for tattoo studios, aesthetic medicine clinics and dental practices, where hygiene breaches pose a direct risk to clients' health. The autoclave is suitable for hospital departments, dental and ophthalmology practices and biological research institutes. It sterilises wrapped (single- and multi-layer) and unwrapped solid products, porous products and hollow objects in accordance with EN 13060:2004+A2:2010. The device is also suitable for non-medical and veterinary use.
Warning: The device is not intended for sterilising liquids.
Class B autoclave - the highest sterilisation class
Lafomed Premium Line - is a Class B medical autoclave, especially recommended for hospital wards, dental and ophthalmology departments, biology institutes, barbershops, beauty salons, tattoo studios and aesthetic medicine clinics. Class B means the highest sterilisation efficiency: the device sterilises unwrapped and wrapped instruments, solid and hollow objects equally reliably - there is no need for a separate autoclave for different types of instruments. Sterilisation with this autoclave delivers full efficiency and safety in line with medical standards.
Functionality you will appreciate
The autoclave is connected to a built-in thermal printer - cycle results are printed without ink, directly after the process, saving time on documentation. The LCD display shows time, temperature, pressure and cycle progress in real time - the practitioner sees the exact process status with no guesswork. The USB port lets you save cycle data to a flash drive, which is important for audits and hygiene control records.
The device has 10 fully automatic programmes: 7 sterilisation, 2 test (Bowie & Dick and vacuum test) and a cleaning programme. In addition, there is a user programme in which all parameters can be set freely. The menu is intuitive, and a programme can be selected in a few seconds. The shortest sterilisation programme takes just 7 minutes (134°C solid, including drying) - especially important for salons with an intensive client flow, where there is no time for long cycles between appointments.
The preheating and temperature holding function (up to 8 hours) shortens each cycle - the autoclave is always ready for work, with no waiting for it to heat up between clients. Built-in clean (distilled) water and used water tanks, with water drainage from the front or rear - no extra external containers are needed, and maintenance is simpler. The self-diagnosis system protects against failures and extends the service life of the device. The double door locking system (mechanical and electronic) provides extra safety during the process.
Key features
-
Class B medical autoclave - the highest class, effectively sterilises wrapped and unwrapped, solid and hollow instruments; no need for two separate devices
-
12 L chamber capacity - suitable for beauty salons, tattoo studios and medical facilities that need to process a larger number of instruments in one cycle
-
Built-in thermal printer - ink-free printing of cycle results; saves time and ensures documentation without extra equipment
-
LCD display and USB port - shows time, temperature, pressure and cycle progress; saving data to a flash drive makes documenting hygiene audits easier
-
10 automatic programmes - 7 sterilisation, 2 test and a cleaning programme; suitable for different types of instruments without extra settings
-
Shortest programme - 7 min. (134°C solid, including drying) - allows instruments to be prepared quickly between clients
-
Grade 304 stainless steel chamber - durable, aesthetic and compliant with hygiene requirements
-
Self-diagnosis system and double door lock - mechanical and electronic protection, reducing the risk of failures during operation
-
ISO 13485 and EN 13060 compliance - certified to medical standards; suitable for facilities that require documented compliance
Automatic sterilisation programmes
| Sterilisation programme |
Pressure |
Total cycle time* |
| 121° Solid |
110 kPa |
23 min |
| 121° Porous |
110 kPa |
27 min |
| 121° Hollow |
110 kPa |
30 min |
| 134° Solid |
210 kPa |
7 min |
| 134° Porous |
210 kPa |
11 min |
| 134° Hollow |
210 kPa |
14 min |
| 135° Prions |
210 kPa |
29 min |
*Indicates the time after the device has warmed up.
The fastest 134°C programme takes just 7 minutes - suitable for salons with a high client flow, where instruments must be ready quickly. The 121°C programmes (23–30 min) are intended for sterilising more delicate instruments at lower pressure.
Specification
| Class B medical |
The highest autoclave class - sterilises unwrapped and wrapped items regardless of instrument type. There is no need to choose a separate device for different packaging. |
| High-quality workmanship |
Manufactured under ISO 13485 certification and meets the requirements of BS EN 13060:2014+A1:2018 - suitable for facilities that require documented compliance during inspections. |
| Capacity 12 L |
The 12-litre capacity allows more instruments to be sterilised in one cycle - suitable for beauty salons and tattoo studios, where a larger set of instruments is used at the same time. |
| Built-in printer |
The thermal printer uses only thermal paper - no ink and no extra equipment needed for documentation. |
| Sterilisation of unwrapped or wrapped instruments |
A Class B autoclave sterilises both unwrapped and wrapped (solid or hollow) instruments - one device for all working needs. |
| The LCD display |
Shows time, temperature, pressure and cycle progress - the practitioner can see the exact process status at any moment. |
| Easy and smooth operation |
Intuitive menus let you quickly select a programme or set parameters - no special technical knowledge required. |
| 10 automatic programmes |
7 sterilisation programmes, 2 test programmes (Bowie & Dick and vacuum test) and a cleaning programme - covering all the needs of a typical practice. |
| Short sterilisation |
The fastest programme takes 7 minutes including drying - instruments are ready quickly without holding up the client flow. Drying time is adjustable. |
| User programme |
An individual sterilisation programme can be set with all parameters - suitable for specific instruments or non-standard needs. |
| Cleaning programme |
Designed for cleaning the autoclave. It is especially indicated when the message "CLEANING REQUIRED" appears on the display - the system itself tells you when it is time to clean. |
| USB port |
Cycle data is saved to a flash drive - documentation is stored digitally and available during audits or inspections. |
| Shortcut function |
The last sterilisation programme used is saved and automatically available when the autoclave is switched on - saving time when the same programme is used every day. |
| Automatic start function |
The programme starts at a preset time - on a specific date and time or after a set number of hours. The autoclave can start working before the practitioner arrives at the salon. |
| Preheating function |
The device heats up before the programme or parameters are set - the first cycle starts sooner, with no waiting for it to warm up. |
| Temperature holding function |
The autoclave maintains a constant warm temperature for up to 8 hours - this shortens each cycle because the chamber is always ready. Suitable for salons with a busy schedule. |
| Built-in clean water and waste water tanks |
The clean water tank is intended for distilled or deionised water. A separate waste water tank means no extra external containers are needed, and maintenance is simpler and cleaner. |
| The self-diagnosis system |
The system detects potential faults and warns in good time - reducing the risk of unplanned breakdowns and extending the service life of the device. |
| Grade 304 stainless steel chamber |
An extremely durable and aesthetic chamber - withstands intensive workloads, is easy to clean and meets hygiene requirements. |
| Double door lock |
Mechanical and electronic protection - the door does not open during the process, ensuring safety and proper cycle completion. |
| High-quality bacteriological filter |
Replaced every 150 cycles - regular maintenance ensures sterilisation quality; filters are available from the Beauty Kit store. |
Watch the video with information on using medical autoclaves:
Specifications
| Certificates and standards |
ISO 13485, BS EN 13060:2014+A1:2018 |
| Power |
2.4 kW |
| Voltage |
230 V |
| Frequency |
50/60 Hz |
| Maximum operating temperature |
137 °C |
| Maximum operating pressure |
0.21–0.23 MPa |
| Design pressure |
-0.1 / 0.27 MPa |
| Pressure safety valve set value |
0.24 MPa |
| Safety valve opening pressure |
0.24 MPa – 0.26 MPa |
| User programme |
All parameters |
| Time control |
4–60 min |
| Drying time |
1–25 min |
| Vacuum pulses |
1–10 times |
| Automatic programmes |
- 134°C Solid
- 134°C Porous
- 134°C Hollow
- 121°C Solid
- 121°C Porous
- 121°C Hollow
- 135°C Prions
- Cleaning
- Vacuum test
- Bowie & Dick / Helix test
|
| Chamber capacity |
12 L |
| Package dimensions |
71 cm × 52 cm × 43.5 cm |
| Dimensions |
63 cm × 43 cm × 36 cm |
| Chamber material |
304 stainless steel |
| Net weight |
47.7 kg |
| Weight with packaging |
59 kg |
The device dimensions - 63 × 43 × 36 cm - allow it to be placed on a work surface in a standard treatment room. The 2.4 kW power ensures fast chamber heating and stable cycles without overheating. Compliance with ISO 13485 and BS EN 13060:2014+A1:2018 provides a documented basis for inspections and hygiene audits.
What's included: Autoclave, drain hose, trays, power cable, tray rack, tray removal handle, fuse, user manual, technical passport.
Frequently asked questions
How long does the fastest programme take?
The 134° programme for solid loads takes 7 min including drying. The 121° programmes take 23–30 min, and the 135° prion programme 29 min (times are counted once the device has warmed up).
How many programmes does the autoclave have?
10 automatic programmes: 7 sterilisation, 2 test (Bowie & Dick and vacuum test) and a cleaning programme. There is also a user programme with freely adjustable parameters.
Do I need to wait for it to warm up between cycles?
The preheating and temperature holding function (up to 8 hours) keeps the autoclave ready for work between clients.
What water should be used, and where is it drained?
There is a built-in clean (distilled) water tank and a used water tank; water can be drained from the front or rear.
How are cycle results recorded?
The thermal printer prints cycle results without ink, and the LCD display shows time, temperature and pressure; data can be saved to a flash drive via USB.