Medical autoclave MONA LCD 18 L - Class B sterilisation equipment meeting professional requirements for dental surgeries, medical practices, veterinary clinics, beauty and spa salons. The device operates on the fractional pre-vacuum principle - currently recognised as the most effective sterilisation method, ensuring guaranteed steam penetration into complex-shaped instruments, porous surfaces and wrapped materials. CE medical certification confirms the device complies with EU medical device standards.

The large 18 L capacity tank allows up to 8 sterilisation cycles without refilling - particularly important for salons with high client throughput, where every minute of downtime costs money. 5 pre-set programmes allow quick selection of the appropriate cycle with a few button presses, without complicated controls - staff can start a cycle and continue with other tasks. Manual mode provides the ability to precisely set drying time (1–60 minutes) according to the type of material being sterilised.

The LCD display ensures clear real-time process visualisation - easy to monitor cycle progress even during intensive work. The integrated thermal printer automatically generates a report for each sterilisation cycle - an essential documentation tool for salons during audits or hygiene inspections, and significantly reduces manual record keeping. Alternating vacuum and steam sequences ensure high sterilisation quality even for complex instruments: needles, catheters, dental instruments and saw blades.

Key Features

  • Class B medical - fractional pre-vacuum: effective sterilisation of complex-shaped and porous instruments
  • 18 L capacity - up to 8 sterilisation cycles without refilling, suitable for high client flow salons
  • 5 pre-set programmes - quick selection without additional settings
  • Manual drying time adjustment (1–60 min) - flexibility for different material types
  • LCD display - clear real-time process monitoring
  • Integrated thermal printer - automatic cycle documentation, suitable for hygiene audits
  • CE medical certification - complies with EU standards
  • Weight: 47 kg

Uses

The autoclave is suitable for sterilising:

  • Scalpels, scissors
  • Porous instruments, such as saw blades, microdermabrasion tips
  • Cotton materials, such as towels
  • Plastic and rubber materials, such as gloves, brushes

Applications

  • Beauty salons
  • Dental surgeries
  • Tattoo studios
  • Medical facilities
  • Hospitals and clinics

Included

  • Class B device, 18 L capacity
  • Three metal trays
  • Tray holder
  • Water drain hose
  • One roll of paper
  • Power cable
  • Instruction manual in English
  • Integrated thermal printer summarising work progress

Dimensions

  • Length: 62 cm
  • Width: 50 cm
  • Height: 43 cm
  • Chamber diameter: 25 cm
  • Chamber depth: 35 cm
  • Weight: 47 kg
  • Package dimensions: 74×52×46 cm
  • Capacity: 18 L
  • Power: 1800 W
  • Voltage: 230 V

1800 W power ensures rapid temperature achievement and stable cycle maintenance without overheating risk. Compact dimensions of 62×50×43 cm allow the autoclave to be conveniently installed even in a small sterilisation zone - suitable for both a separate sterilisation room and a work zone in a surgery.

Product form

Medical Autoclave MONA LCD 18 L Class B with Printer

SKU: 204773
Barcode: 5906508742419

2 269,00 € 2 155,60 €

  •  This item is currently out of stock.

Out of stock

  • Easy returns
  • Free delivery
  • Masters discounts

Description

Medical autoclave MONA LCD 18 L - Class B sterilisation equipment meeting professional requirements for dental surgeries, medical practices, veterinary clinics, beauty and spa salons. The device operates on the fractional pre-vacuum principle - currently recognised as the most effective sterilisation method, ensuring guaranteed steam penetration into complex-shaped instruments, porous surfaces and wrapped materials. CE medical certification confirms the device complies with EU medical device standards.

The large 18 L capacity tank allows up to 8 sterilisation cycles without refilling - particularly important for salons with high client throughput, where every minute of downtime costs money. 5 pre-set programmes allow quick selection of the appropriate cycle with a few button presses, without complicated controls - staff can start a cycle and continue with other tasks. Manual mode provides the ability to precisely set drying time (1–60 minutes) according to the type of material being sterilised.

The LCD display ensures clear real-time process visualisation - easy to monitor cycle progress even during intensive work. The integrated thermal printer automatically generates a report for each sterilisation cycle - an essential documentation tool for salons during audits or hygiene inspections, and significantly reduces manual record keeping. Alternating vacuum and steam sequences ensure high sterilisation quality even for complex instruments: needles, catheters, dental instruments and saw blades.

Key Features

  • Class B medical - fractional pre-vacuum: effective sterilisation of complex-shaped and porous instruments
  • 18 L capacity - up to 8 sterilisation cycles without refilling, suitable for high client flow salons
  • 5 pre-set programmes - quick selection without additional settings
  • Manual drying time adjustment (1–60 min) - flexibility for different material types
  • LCD display - clear real-time process monitoring
  • Integrated thermal printer - automatic cycle documentation, suitable for hygiene audits
  • CE medical certification - complies with EU standards
  • Weight: 47 kg

Uses

The autoclave is suitable for sterilising:

  • Scalpels, scissors
  • Porous instruments, such as saw blades, microdermabrasion tips
  • Cotton materials, such as towels
  • Plastic and rubber materials, such as gloves, brushes

Applications

  • Beauty salons
  • Dental surgeries
  • Tattoo studios
  • Medical facilities
  • Hospitals and clinics

Included

  • Class B device, 18 L capacity
  • Three metal trays
  • Tray holder
  • Water drain hose
  • One roll of paper
  • Power cable
  • Instruction manual in English
  • Integrated thermal printer summarising work progress

Dimensions

  • Length: 62 cm
  • Width: 50 cm
  • Height: 43 cm
  • Chamber diameter: 25 cm
  • Chamber depth: 35 cm
  • Weight: 47 kg
  • Package dimensions: 74×52×46 cm
  • Capacity: 18 L
  • Power: 1800 W
  • Voltage: 230 V

1800 W power ensures rapid temperature achievement and stable cycle maintenance without overheating risk. Compact dimensions of 62×50×43 cm allow the autoclave to be conveniently installed even in a small sterilisation zone - suitable for both a separate sterilisation room and a work zone in a surgery.

*Atspalviai ir spalvos nuotraukose gali skirtis nuo spalvų realybėje.

Items viewed

additional information

How long does it take for the goods to be delivered?

The goods in the warehouse and in the store are sent within 1-2 working days after receiving the payment. Other items are shipped within 4-8 business days.

How are the goods delivered?

Parcels are delivered by Omniva and Venipak couriers to the address you specify or to the Omniva, Venipak or LP Express post office specified by you.

Where can I check the status of my order?

Registered customers can monitor order status and order history through their account. After logging in to your account, click "Orders ". Unregistered customers can find all the information by clicking on the link in e-mail. in the "Order Confirmation" letter.

Lojalumo taškai po kiekvieno užsakymo - Beauty Kit

Loyalty program

After joining the loyalty program, the amount of your every purchase turns into loyalty points and accumulates in your profile. You can become a member of the loyalty program by creating an account by e-mail. on the page beautykit.lt

  • Collect points for every order you make
  • Use available points at checkout

More information 

Login

Forgot your password?

Don't have an account yet?