Description

The BR-062 device uses TECAR technology and is suitable for aesthetic clinics and beauty salons. It operates at a radiofrequency of 448 kHz.

TECAR therapy is based on restoring the natural biological balance of cells and their membranes - this allows work not only on the skin surface, but also on deeper tissue layers. The device gradually raises temperature at cellular level: as a result, skin firms, connective tissue contracts and its structure improves.

The BR-062 is suitable for cellulite reduction protocols, helps smooth wrinkles and work with scars. Collagen synthesis stimulation and fibroblast activation contribute to improved skin elasticity.

BR-062 device benefits

  • gently raises body temperature - suitable for general toning procedures;
  • supports tissue regeneration and cellular metabolism;
  • suitable for cellulite and fatty tissue reduction procedures;
  • delivers energy to tissues - maintains procedure effects between sessions;
  • suitable for combined body and rehabilitation procedures.

TECAR - Capacitive and Resistive Energy Transfer therapy - uses high-frequency electrical current for tissue stimulation and supporting regeneration processes. This method is characterised by four main effects:

  • Increased microcirculation - TECAR promotes blood and lymph flow, improves tissue oxygen supply and nutrient transport.
  • Vasodilation - cells receive more oxygen and nutrients, metabolism and regeneration accelerate.
  • Muscle relaxation - reduces muscle tension, suitable for combined body procedures.
  • Cell regeneration support - stimulates natural regeneration processes.

Two types of electrodes are used during procedures: capacitive (CET) and resistive (RET). CET electrodes are designed for therapy of tissues near the skin surface, RET - for deeper tissues and multi-joint regions. The procedure is painless and non-invasive - clients feel pleasant warmth, making it suitable for work with more sensitive clients.

Two operating modes

CAP mode operates on the principle of tissue stimulation in an electrical field. An insulated CET electrode placed on the skin creates an insulating layer that allows electrical impulses to be transmitted to deeper tissue layers. Therapeutic effects concentrate in the area below the skin surface and in soft tissues - muscles and lymphatic system, which have better electrical conductivity due to higher water content.

CAP mode contributes to:

  • improved skin firmness and reduced signs of ageing;
  • revitalised microcirculation - supports better tissue nutrition;
  • increased blood vessel elasticity;
  • delivery of active components to fibroblasts - supports their function;
  • increased active oxygen flow in cells;
  • strengthened collagen synthesis - important for maintaining skin elasticity.

RES mode - resistive mode with RET electrodes, applied to improve circulation, reduce fatty tissue and support tissue regeneration. During the procedure, electrical energy generated by the electrodes is converted to heat, which is absorbed by tissues with higher resistance - this improves cellular metabolism and stimulates regeneration processes. The combination of two modes allows the device to be adapted for both beauty and rehabilitation procedures.

Main features

  • TECAR technology, 448 kHz frequency.
  • Power: 55 W, voltage: 230 V - stable operation on standard salon electrical supply.
  • Two operating modes: CAP and RES - one device for two different depth procedure protocols.
  • Two electrode types: CET and RET - flexible adaptation to different body areas.
  • Suitable for skin regeneration, cellulite reduction, wrinkle smoothing and rehabilitation.
  • Procedure is painless and non-invasive - suitable for work with more sensitive clients.
  • Suitable for aesthetic clinics and beauty salons.

55 W power ensures stable device operation even on intensive working days. The device operates from a standard 230 V supply - no additional electrical installation required in the salon.

Product form

Radiofrequency Device 448 kHz BR-062

SKU: 218705
Barcode: 5906508748015

696,00 € 611,90 €

🚚 Estimated delivery time:  

October 02 d. - October 09 d.

🚚 Estimated delivery time:  

September 28 d. - September 29 d.

    Out of stock

    • Easy returns
    • Free delivery
    • Masters discounts

    Description

    The BR-062 device uses TECAR technology and is suitable for aesthetic clinics and beauty salons. It operates at a radiofrequency of 448 kHz.

    TECAR therapy is based on restoring the natural biological balance of cells and their membranes - this allows work not only on the skin surface, but also on deeper tissue layers. The device gradually raises temperature at cellular level: as a result, skin firms, connective tissue contracts and its structure improves.

    The BR-062 is suitable for cellulite reduction protocols, helps smooth wrinkles and work with scars. Collagen synthesis stimulation and fibroblast activation contribute to improved skin elasticity.

    BR-062 device benefits

    • gently raises body temperature - suitable for general toning procedures;
    • supports tissue regeneration and cellular metabolism;
    • suitable for cellulite and fatty tissue reduction procedures;
    • delivers energy to tissues - maintains procedure effects between sessions;
    • suitable for combined body and rehabilitation procedures.

    TECAR - Capacitive and Resistive Energy Transfer therapy - uses high-frequency electrical current for tissue stimulation and supporting regeneration processes. This method is characterised by four main effects:

    • Increased microcirculation - TECAR promotes blood and lymph flow, improves tissue oxygen supply and nutrient transport.
    • Vasodilation - cells receive more oxygen and nutrients, metabolism and regeneration accelerate.
    • Muscle relaxation - reduces muscle tension, suitable for combined body procedures.
    • Cell regeneration support - stimulates natural regeneration processes.

    Two types of electrodes are used during procedures: capacitive (CET) and resistive (RET). CET electrodes are designed for therapy of tissues near the skin surface, RET - for deeper tissues and multi-joint regions. The procedure is painless and non-invasive - clients feel pleasant warmth, making it suitable for work with more sensitive clients.

    Two operating modes

    CAP mode operates on the principle of tissue stimulation in an electrical field. An insulated CET electrode placed on the skin creates an insulating layer that allows electrical impulses to be transmitted to deeper tissue layers. Therapeutic effects concentrate in the area below the skin surface and in soft tissues - muscles and lymphatic system, which have better electrical conductivity due to higher water content.

    CAP mode contributes to:

    • improved skin firmness and reduced signs of ageing;
    • revitalised microcirculation - supports better tissue nutrition;
    • increased blood vessel elasticity;
    • delivery of active components to fibroblasts - supports their function;
    • increased active oxygen flow in cells;
    • strengthened collagen synthesis - important for maintaining skin elasticity.

    RES mode - resistive mode with RET electrodes, applied to improve circulation, reduce fatty tissue and support tissue regeneration. During the procedure, electrical energy generated by the electrodes is converted to heat, which is absorbed by tissues with higher resistance - this improves cellular metabolism and stimulates regeneration processes. The combination of two modes allows the device to be adapted for both beauty and rehabilitation procedures.

    Main features

    • TECAR technology, 448 kHz frequency.
    • Power: 55 W, voltage: 230 V - stable operation on standard salon electrical supply.
    • Two operating modes: CAP and RES - one device for two different depth procedure protocols.
    • Two electrode types: CET and RET - flexible adaptation to different body areas.
    • Suitable for skin regeneration, cellulite reduction, wrinkle smoothing and rehabilitation.
    • Procedure is painless and non-invasive - suitable for work with more sensitive clients.
    • Suitable for aesthetic clinics and beauty salons.

    55 W power ensures stable device operation even on intensive working days. The device operates from a standard 230 V supply - no additional electrical installation required in the salon.

    *Atspalviai ir spalvos nuotraukose gali skirtis nuo spalvų realybėje.

    Items viewed

    additional information

    How long does it take for the goods to be delivered?

    The goods in the warehouse and in the store are sent within 1-2 working days after receiving the payment. Other items are shipped within 4-8 business days.

    How are the goods delivered?

    Parcels are delivered by Omniva and Venipak couriers to the address you specify or to the Omniva, Venipak or LP Express post office specified by you.

    Where can I check the status of my order?

    Registered customers can monitor order status and order history through their account. After logging in to your account, click "Orders ". Unregistered customers can find all the information by clicking on the link in e-mail. in the "Order Confirmation" letter.

    Lojalumo taškai po kiekvieno užsakymo - Beauty Kit

    Loyalty program

    After joining the loyalty program, the amount of your every purchase turns into loyalty points and accumulates in your profile. You can become a member of the loyalty program by creating an account by e-mail. on the page beautykit.lt

    • Collect points for every order you make
    • Use available points at checkout

    More information 

    Login

    Forgot your password?

    Don't have an account yet?