Description
The BR-062 device uses TECAR technology and is suitable for aesthetic clinics and beauty salons. It operates at a radiofrequency of 448 kHz.
TECAR therapy is based on restoring the natural biological balance of cells and their membranes - this allows work not only on the skin surface, but also on deeper tissue layers. The device gradually raises temperature at cellular level: as a result, skin firms, connective tissue contracts and its structure improves.
The BR-062 is suitable for cellulite reduction protocols, helps smooth wrinkles and work with scars. Collagen synthesis stimulation and fibroblast activation contribute to improved skin elasticity.
BR-062 device benefits
- gently raises body temperature - suitable for general toning procedures;
- supports tissue regeneration and cellular metabolism;
- suitable for cellulite and fatty tissue reduction procedures;
- delivers energy to tissues - maintains procedure effects between sessions;
- suitable for combined body and rehabilitation procedures.
TECAR - Capacitive and Resistive Energy Transfer therapy - uses high-frequency electrical current for tissue stimulation and supporting regeneration processes. This method is characterised by four main effects:
- Increased microcirculation - TECAR promotes blood and lymph flow, improves tissue oxygen supply and nutrient transport.
- Vasodilation - cells receive more oxygen and nutrients, metabolism and regeneration accelerate.
- Muscle relaxation - reduces muscle tension, suitable for combined body procedures.
- Cell regeneration support - stimulates natural regeneration processes.
Two types of electrodes are used during procedures: capacitive (CET) and resistive (RET). CET electrodes are designed for therapy of tissues near the skin surface, RET - for deeper tissues and multi-joint regions. The procedure is painless and non-invasive - clients feel pleasant warmth, making it suitable for work with more sensitive clients.
Two operating modes
CAP mode operates on the principle of tissue stimulation in an electrical field. An insulated CET electrode placed on the skin creates an insulating layer that allows electrical impulses to be transmitted to deeper tissue layers. Therapeutic effects concentrate in the area below the skin surface and in soft tissues - muscles and lymphatic system, which have better electrical conductivity due to higher water content.
CAP mode contributes to:
- improved skin firmness and reduced signs of ageing;
- revitalised microcirculation - supports better tissue nutrition;
- increased blood vessel elasticity;
- delivery of active components to fibroblasts - supports their function;
- increased active oxygen flow in cells;
- strengthened collagen synthesis - important for maintaining skin elasticity.
RES mode - resistive mode with RET electrodes, applied to improve circulation, reduce fatty tissue and support tissue regeneration. During the procedure, electrical energy generated by the electrodes is converted to heat, which is absorbed by tissues with higher resistance - this improves cellular metabolism and stimulates regeneration processes. The combination of two modes allows the device to be adapted for both beauty and rehabilitation procedures.
Main features
- TECAR technology, 448 kHz frequency.
- Power: 55 W, voltage: 230 V - stable operation on standard salon electrical supply.
- Two operating modes: CAP and RES - one device for two different depth procedure protocols.
- Two electrode types: CET and RET - flexible adaptation to different body areas.
- Suitable for skin regeneration, cellulite reduction, wrinkle smoothing and rehabilitation.
- Procedure is painless and non-invasive - suitable for work with more sensitive clients.
- Suitable for aesthetic clinics and beauty salons.
55 W power ensures stable device operation even on intensive working days. The device operates from a standard 230 V supply - no additional electrical installation required in the salon.
Frequently asked questions
What frequency does the BR-062 operate at and what is its power?
The device works with 448 kHz radio waves (TECAR technology) and has a power of 55 W. It plugs into a standard 230 V mains socket.
What is the difference between the CAP and RES modes?
In CAP mode you work with an insulated CET electrode – the effect is concentrated just below the skin surface and in the soft tissues. RES mode uses RET electrodes intended for deeper tissues, circulation and fatty tissue.
Which treatments is this device suitable for?
For reducing cellulite and fatty tissue, smoothing wrinkles, working on scars, skin tightening and combined body and rehabilitation treatments.
Is the treatment painful?
No, the treatment is non-invasive – the client feels a pleasant warmth, so it can also be used on more sensitive clients.